Название: Control of surface aktive agents content in agueous environment by measuring surface tension
Другие названия: Контроль вмісту поверхнево-активних речовин у водних середовищах шляхом вимірювання їх поверхневого натягу
Авторы: Kisil, I. S.
Bodnar, R. T.
Patlovskyy, I. R.
Malko, O. H.
Kuchirka, Yu. M.
Ключевые слова: aqueous environment
concentration
control
maximum pressure in the bubble
measurement
pulsing meniscus
surface-active agent
surface tension
Дата публикации: 2014
Издательство: Ivano-Frankivsk National Technical University of Oil and Gas
Библиографическое описание: Control of surface aktive agents content in agueous environment by measuring surface tension = Контроль вмісту поверхнево-активних речовин у водних середовищах шляхом вимірювання їх поверхневого натягу / I. S. Kisil, R. T. Bodnar, I. R. Patlovskyy [et al.] // Journal of Hydrocarbon Power Engineering. - 2014. - Vol. 1, № 1. - P. 66-72.
Краткий осмотр (реферат): Surface tention (ST) is a physical-chemical parameter that informs about the presence of surface-active agents (surfactants) in the aqueous environment. The article proposes to obtain experimentally ST (1ST) time dependence of the controlled aqueous environment and to judge by the equilibrium ST value (EST) about the surfactant concentration in such an environment, based on the previously received calibration dependence of EST on the concentration of respective surfactant in the aqueous environment. EST dependence of controlled aqueous environment is recommended to get though ST measurements by pulsing meniscus method based on the measurement of maximum pressure in the bubble (MPB) without its separation.The essence of pulsing meniscus method has been described. The advantage of this method over usual MPB method is that in the process of obtaining 1ST dependence and EST value one should use the same air meniscus surface at the end of metering capillary submerged in the sample of the investigated aqueous environment. It considerably speeds up the process of getting 1ST dependence and EST value of aqueous environment. The article contains a block diagram, appearance and work description of a device that implements pulsing meniscus method with the application of microcontrollers and hydraulic damper of depth of the metering capillary submersion in the controlled aqueous environment. Calculation of ST value on the basis of the measured maximum pressure drop Afmax m me meniscus pulsation process could be accomplished by one of the proposed dependences and methods (M. Cantor, R. Feustel, E. Schrodinger, J. Dugne, S. Sudgen, R. Bendure, I. Kisil). Recommended ranges of values for the parameter Apgr/Apm;a have been demonstrated, where relative methodological error of the calculation results of ST values will not exceed 0.1%, where Ap is the densities difference of the controlled aqueous environment and air, g is the acceleration of free fall and r is an outlet radius of the device metering capillary.
URI (Унифицированный идентификатор ресурса): http://elar.nung.edu.ua/handle/123456789/102
Располагается в коллекциях:Journal of Hydrocarbon Power Engineering. - 2014. - Vol. 1, № 1